Product FeaturesMulti-axis force sensor is a kind of force sensor which can measure the force and torque components in more than two directions simultaneously. Multi - axis force sensors are divided into two - axis force sensors, three - axis force sensors and six - axis force sensors. The three-axis force sensor can simultaneously detect the change of force value in three directions, X axis, Y axis, Z axis (vertical force), and output three groups of voltage signals. Three-dimensional force sensor, high-speed sampling, high-speed dynamic response, anti-interference, long-term stable performance, sensitive response; |
Technical Specifications
Specfications | Technique |
Maximum capacity (Emax) | 50,100,150,200,250,300,400,500,600,750kg;1.0,1.5,2.0t |
Accuracy class | C3 |
Maximum number of load cell intervals (nLC) | 3000 |
Ratio of minimum LC verification interval Y=Emax / Vmin | 10000 |
Combined error | ≤ ±0.020%FS |
Creep | ≤ ±0.016%FS/30min |
Temperature effect on sensitivity | ≤ ±0.011%FS/10℃ |
Temperature effect on zero | ≤ ±0.015%FS/10℃ |
Output sensitivity (=FS) | 2.0±0.2mV/V |
Input resistance | 384±4Ω |
Output resistance | 351±2.0Ω |
Insulation resistance | ≥ 5000MΩ(50VDC) |
Zero balance | ≤ ±1.5%FS |
Compensated temperature | -10 ~+40℃ |
Operating temperature | -35 ~+70℃ |
Excitation recommended voltage | 5 ~ 12VDC |
Excitation maximum | 18VDC |
Safe overload | 150%FS |
Ultimate overload | 300%FS |
Corner correction | 0.02%load value/100mm |
ATEX classification (optional) | II1GExia II1CT4/II1DExiaD20 T73℃/ II3GExnLIICT4 |
Wiring | Red: Input+, Brown:Sense+,Blue: Output+, Shield: Transparent, Black: Sense-, Yellow:Input-,White: Output- Adopt shielded, 4 conductor cable: φ6.2mm; Standard cable length: 3m |