SL5126 Bench Scale Single Point Load Cell
For customised ranges, accuracy, dimensions and other parameters, please contact us.
Product FeaturesMulti-axis force sensor is a kind of force sensor which can measure the force and torque components in more than two directions simultaneously. Multi - axis force sensors are divided into two - axis force sensors, three - axis force sensors and six - axis force sensors. The three-axis force sensor can simultaneously detect the change of force value in three directions, X axis, Y axis, Z axis (vertical force), and output three groups of voltage signals. Three-dimensional force sensor, high-speed sampling, high-speed dynamic response, anti-interference, long-term stable performance, sensitive response; |
Technical Specifications
Specfications | Technique | ||
Maximum capacity (Emax) | 50/60/80/100/150/200/250/300/400/500kg | ||
Output sensitivity (=FS) | 2.0±0.2mV/V | ||
Accuracy class | C3 | C4 | C5 |
Combined error | ±0.02%FS | Emax/15000 Vmin | OIML R60 C4 |
Creep | ±0.0167%FS/30min | ≤ ±0.018%FS | OIML R60 C4 |
Temperature effect on sensitivity | ±0.0175%FS/10℃ | ≤ ±0.012%FS/30min | OIML R60 C4 |
Temperature effect on zero | ±0.02%FS/10℃ | ≤ ±0.009%FS/10℃ | OIML R60 C4 |
Zero balance | ±2%FS | ||
Compensated temperature | -10~40℃ | ||
Operating temperature | -35~65℃ | ||
Input resistance | 406±6Ω | ||
Output resistance | 350±3Ω | ||
Insulation resistance | ≥5000MΩ(50VDC) | ||
Excitation, recommended voltage | 5~12VDC | ||
Excitation maximum | 18VDC | ||
Safe overload | 120%FS | ||
Ultimate overloadProtection | 150%FS | ||
Class | IP65 | ||
Cable specification | φ5.3mm | ||
Cable length | 2m | ||
Recommended scale size | 400x400mm | ||
Corner correction | 0.02% load value/100mm | ||
Recommended torque on fixation | 20N.m | ||
Wiring | Red: Input+, Green: Output+, Transparent: Shield,Black: Input-,White: Output- |
Product Dimensions
Installation size
Load Direction
Wiring Diagram
Accurate measurement with matching display
The output of the force measuring and weighing sensor itself is an MV signal, which needs to be amplified and convertedto display numerical values or output signals to the upper computer, PLC, etc.
Request For Quote