SLBM24R Hermetically sealed Load Cell
For customised ranges, accuracy, dimensions and other parameters, please contact us.
Technical Specifications
Specfications | Technique | ||||||||
Maximum capacity (Emax) | 60kg / 130kg / 280kg / 250kg / 500kg / 1t / 2t / 3.5t / 5t/ 10t / 13t / 28t / 60t | ||||||||
Accuracy class | C2 | C3 | C4 | C5 | |||||
Approvals |
| OIML R60 C3 | OIML R60 C4 | OIML R60 C5 | |||||
Maximum number of load cell intervals (nLC) | 2000nmax | 3000nmax | 4000 | 5000 | |||||
Ratio of minimum LC verification interval Y=Emax / Vmin | Emax/5000Vmin | Emax/10000Vmin | Emax/14000Vmin | Emax/16000Vmin | |||||
Combined error | ≤±0.0300%FS | ≤±0.0230%FS | ≤±0.0173%FS | ≤±0.0140%FS | |||||
Creep | ≤±0.0245%FS/30min | ≤±0.0245%FS/30min | ≤±0.0184%FS/30min | ≤±0.0147%FS/30min | |||||
Temperature effect on sensitivity | ≤±0.0175%FS/10℃ | ≤±0.0117%FS/10℃ | ≤±0.0088%FS/10℃ | ≤±0.0070%FS/10℃ | |||||
Temperature effect on zero | ≤±0.0280%FS/10℃ | ≤±0.0140%FS/10℃ | ≤±0.0100%FS/10℃ | ≤±0.0088%FS/10℃ | |||||
Output sensitivity (= FS) | 60kg / 130kg / 280kg | 250kg | 500kg ~ 60t | ||||||
| 1.0±0.1mV/V | 1.75±0.1mV/V | 2.0±0.1mV/V | ||||||
Input resistance | 60kg / 130kg / 280kg | 250kg /500kg~10t | 13t | 28t | 60t | ||||
| 1260±100Ω | 1100±100Ω | 1200±100Ω | 1075±100Ω | 1350±200Ω | ||||
Output resistance | 60kg / 130kg / 280kg | 250kg /500kg~10t | 13t | 28t | 60t | ||||
| 1020±0.5Ω | 1025±25Ω | 1000±0.5Ω | 930±0.5Ω | 1175±0.5Ω | ||||
Insulation resistance | ≥5000MΩ(50VDC) | ||||||||
Zero balance | ≤±1.0%FS ~ | ||||||||
Compensated temperature | -10 +40℃ ~ | ||||||||
Operating temperature | -35 +70℃ | ||||||||
Excitation, recommended voltage | 5~12VDC | ||||||||
Excitation maximum | 18VDC | ||||||||
Safe overload | 150%FS | ||||||||
Ultimate overload | 300%FS | ||||||||
Ingress protection (according to EN 60529) | 60kg /130kg / 280kg | 250kg /500kg~10t | 13t | 28t | 60t | ||||
| 8N.m | 10N.m | —— | —— | —— |
Stainless steel IP68 low profile load cell Hermetically sealed
Suitable for hopper, platform and pallet scales
Integrated static overload protection up to 13t
Accurate measurement with matching display
The output of the force measuring and weighing sensor itself is an MV signal, which needs to be amplified and convertedto display numerical values or output signals to the upper computer, PLC, etc.
Request For Quote