SL605 Inline Rotary Torque Sensor

Dynamic Rotary Torque Sensor

Capacity: 0~0.1,0.2,0.3,0.5, 1~5N.m

Category: Dynamic Rotary Torque Sensor

For customised ranges, accuracy, dimensions and other parameters, please contact us.

SL605.JPG

Product Features

It can measure both static torque and rotating torque;
               Both static torque and dynamic torque can be measured;
               High detection accuracy, good stability; strong anti-interference;
               Small size, light weight, various installation structures, easy to install and use;
               Continuous measurement of forward and reverse torque without repeated zero adjustment;
               There are no wearing parts such as conductive rings, and it can run at high speed for a long time;
               The high-level frequency signal output by the sensor can be directly sent to the computer for processing;
               Measure the strength of the elastic body and can withstand 100% overload

Technical Specifications

SpecificationTechnical Indicators
Capacity0~0.1,0.2,0.3,0.5,
                   1~5N.m
Rated Output    

1~1.5mV/V

Zero Balance±2%F.S.
Creep(30min)≤±0.03%F.S./30min
Non-linearity±0.1,±0.3%F.S.
Hysteresis≤±0.05%F.S.
Repeatability≤0.05%F.S.
Input impedance750±10Ω
Output impedance
700±5Ω
Temperature Sensitivity Drift0.1%F.S./10℃
Zero Temperature Drift0.1%F.S./10℃
Temp. effect on output
0.03%F.S./10℃
Wiring
Red: EXC+, Green: Sig+, Yellow: Shielding wire, White: Sig-, Black: EXC
Temp. effect on zero
0.03%F.S./10℃
Insulation Resistance≥5000MΩ/100V(DC)
Recommended Excitation10~15V
Compensated Temp Range-10~60℃
Operating Temp Range-20~65℃
Safe Overload
150%F.S.
Ultimate Overload
200%F.S.
Cable Size
φ5.2x3m
Material
Stainless Steel/Alloy steel

Product Dimensions

Installation size

SL605-1.JPG

Load Direction

SL605-2.JPG

Wiring Diagram

SL605-3.JPG

Accurate measurement with matching display

The output of the force measuring and weighing sensor itself is an MV signal, which needs to be amplified and convertedto display numerical values or output signals to the upper computer, PLC, etc.

Up: SL604

Next: SL606

Request For Quote