R520S
R520S COMPRESSION LOAD CELL

Product description:

R520S is a large range capacity compression load cell, capacity is from 1t to 470t. It is widely suitable for applications in truck scale and heavy-duty process weighing industry, it is with smooth electro-polished surfaces so that it is easy to be cleaned, and is ideally suited to weighing applications in clean-in-place/sterilize-in-place environments. Full stainless steel constructure, completely hermetically sealed by laser. Also it is designed with mandrel with self-aligning arc point to receive force vertically to ensure the high force accuracy.

Main Features:

• Material: Alloy steel

• Rated Capacities: 1t~470t

• OIML R60, NTEP HB44, CE and RoHS certified

• IP Rating: IP68

• Suitable for truck scales and giant hopper scale.

• High precision by OIML R60 C3, high reliability.


Category: Compression

For customised ranges, accuracy, dimensions and other parameters, please contact us.

ParameterUnitsSpecification
Model No.
R520S
Rated capacity (Emax)t1t … 470t
Min. dead loadkg0
Rated outputmV/V2.85 ± 0.1%
Zero balance% of Emax± 1
Combined error 1)2)% of Emax< ± 0.05
Repeatability error% of AL 3)< ± 0.02
Creep; 30 minute% of AL< ± 0.03
Min. dead load output return (DR); 30 min% of AL< ± 0.03
Temp. effect onMin. dead load output% of Emax/℃< ± 0.002
Rated output 2)% of AL/℃< ± 0.002
Temperature rangeCompensated℃(°F)-10 to +40 [+14 to +104]
Operating-30 to +65 [-22 to +149]
Safe storage-40 to +80 [-40 to +176]
Excitation voltageRecommendedV AC/DC5 ~ 30
Maximum60
Terminal resistanceExcitationΩ1530 ± 10 [Optional: 4400 ± 50]
Output1400 ± 3 [Optional: 4000 ± 10]
Insulation resistance @50VDC>5000
Breakdown voltageV AC>500
Seal type / IP ratingHermetically welded / IP68
Load limitSafe% of Emax150
Ultimate200
MaterialSpring element
Stainless steel
Cable
Φ6; 4-wire; PVC
Cable lengthm1t … 15t22t … 47t68t … 470t
6
12
16
Weight; approxkg1t~4.7t10t~22t33t47t~68t100~150t220~470t
0.71.32.14.68.0
Fatigue lifecycles @Emax>1,000,000
Deflection at Emax; approxmm<1.0
Notes: 
1) Error due to the combined effect of non-linearity and hysteresis
2) The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44
3) AL = Applied Load


Up: R510S

Next: R530A