Product Category

S515 SERIES S-BEAM LOAD CELL
Product description:
S515 is a square-shaped tension & compression load cell, high-quality silica gel potting is to ensure it can work in harsh environment. Available in a wide range of capacities from 1KN to 10KN
Main Features:
• Material: Alloy steel ( thread)
• Rated Capacity: 1KN~10KN
• Calibrated based on criterion of ISO 376
• IP Rating: IP66
• Suitable for force measurement and overloading safety controlling.
• High precision by ISO 376 class 0.5, 1, 2.
For customised ranges, accuracy, dimensions and other parameters, please contact us.
Parameter | Units | Specification |
Parameter | Units | Specification | |||
Model No. | S515A | ||||
Rated capacity (Emax) | kN | 1 / 2 / 5 / 10 | |||
Accruacy class 1)2) | 0.5 00 | ||||
Min. dead load | N | 0 | |||
Rated output | mV/V | 3.0 ± 0.003 | |||
Zero balance | % of Emax | ± 1 | |||
Repeatability error | % of AL 3) | < ± 0.010 < ± 0.006 | |||
Creep; 30 minute | % of AL | < ± 0.017 < ± 0.010 | |||
Min. dead load output return (DR); 30 min | % of AL | < ± 0.017 < ± 0.010 | |||
Temp. effect on | Min. dead load output | % of Emax/℃ | < ± 0.0020 < ± 0.0014 | ||
Rated output 2) | % of AL/℃ | < ± 0.0012 < ± 0.0007 | |||
Temperature range | Compensated | ℃(°F) | -10 to +40 [+14 to +104] | ||
Operating | -40 to +65 [-40 to +149] | ||||
Safe storage | -40 to +80 [-40 to +176] | ||||
Excitation voltage | Recommended | V AC/DC | 5 ~ 15 | ||
Maximum | 15 | ||||
Terminal resistance | Excitation | Ω | 384 ± 5 | ||
Output | 350 ± 3 | ||||
Insulation resistance @50VDC | MΩ | >5000 | |||
Breakdown voltage | V AC | >500 | |||
Seal type / IP rating | Silicon rubber / IP66 | ||||
Load limit | Safe | % of Emax | 140 | ||
Ultimate | 200 | ||||
Material | Spring element | Alloy steel; Nickel plated | |||
Cable | Φ5.6; 4-wire; PVC | ||||
Cable length | m | 5.0 | |||
Weight; approx | kg | 1-5 kN | 10 KIb | ||
0.8 | 1.0 | ||||
Fatigue life | cycles @Emax | >1,000,000 | |||
Deflection at Emax; approx | mm | <1.0 | |||
Barometric pressure effect on Zero Output | Vmin/kPa | <1.0 | |||
Notes: | |||||
1) Error due to the combined effect of non-linearity and hysteresis | |||||
2) The sum of errors due to Temperature Effect on Output comply with the requirements of OIML R60 and NIST HB44 | |||||
3) AL = Applied Load |
Request For Quote